XPS and PS Foam Extrusion: Reference Tables and Specifications
A board passes inspection or it does not, and three things decide which: whether the grade printed on it matches what was ordered, whether it measures inside tolerance, and whether the parameters behind both were written down before the line went on the floor. The first two cost a shipment. The third costs a rebuild.
1 How a board grade is written
GB/T 10801.2-2018 marks a board in six segments, in a fixed order. Once you can read the string, a datasheet stops being a wall of numbers:
XPS-X250-SL-B1-024-GB/T10801.2-2018
| Segment | Meaning | Values |
|---|---|---|
| 1 | Product | XPS |
| 2 | Type (compressive strength and skin) | X150 to X900, ten steps, skinnedW200 / W300, unskinned |
| 3 | Edge profile | SS square / SL shiplap / TG tongue-and-groove / RC rain channel |
| 4 | Reaction to fire | B1 / B2, classified to GB 8624 |
| 5 | Thermal conductivity | 024 / 030 / 034 — ≤0.024 / 0.030 / 0.034 W/(m·K) |
| 6 | Standard | GB/T10801.2-2018, written without spaces |
The number inside the type code is the minimum compressive strength, so X250 means ≥250 kPa and X500 means ≥500 kPa. A density figure does not tell you the same thing: two boards at the same density can sit in different grades.
The code classifies a board; it does not declare conformance. Two boards carrying the same string can still differ in which clause was applied to which property, how the declaration is worded, and what has to be redone when a buyer asks for EN 13164 instead of the GB grade. Those are settled against the clause text at handover.
2 Standard dimensions and tolerances
The standard fixes a set of preferred sizes. Anything outside them is by agreement between buyer and supplier.
| Dimension | Standard values (mm) |
|---|---|
| Length L | 600 · 1,200 · 1,800 · 2,400 |
| Width B | 600 · 900 · 1,200 |
| Thickness H | 10 · 20 · 25 · 30 · 40 · 50 · 75 · 100 · 120 · 150 |
The permitted deviation depends on the size of the board, not on how good the line is:
| Item | Condition (mm) | Permitted deviation (mm) |
|---|---|---|
| Thickness H | H < 75 | −1 / +2 |
| Thickness H | H ≥ 75 | −1 / +3 |
| Length or width | L or B < 1,000 | ±5.0 |
| Length or width | 1,000 ≤ L or B < 2,000 | ±7.5 |
| Length or width | L or B ≥ 2,000 | ±10.0 |
| Diagonal difference | T < 1,000 | ≤ 5.0 |
| Diagonal difference | 1,000 ≤ T < 2,000 | ≤ 7.0 |
| Diagonal difference | T ≥ 2,000 | ≤ 13.0 |
A line can hold thickness tighter than the standard allows, and suppliers often quote that tighter figure. It is a machine capability. The tolerance in the standard is what the board is inspected against. Put the two in separate columns of a contract, or the first delivery argument is about which one applies.
3 What to fix before a quotation means anything
Each of these changes what the line is. Left open, the value is decided by whoever builds it, and it is decided after the price is agreed.
| Parameter | Typical range | Why it has to be written down |
|---|---|---|
| Board width | 450–1,250 mm | Sets the width of the calibrator, haul-off and cross-cut. Cannot be widened once the line is on the floor. |
| Board thickness | 20–150 mm | Sets the die flow channel and the calibrator stroke. |
| Output | 350–3,000 kg/h | Tied to the screw configuration. A quoted figure is meaningless without the recipe and test conditions behind it. |
| Screw L/D | 55:1 | Drives plasticising and mixing. A short L/D struggles on heavily filled compounds. |
| Max screw speed | 1,200 rpm | Combined with the gearbox ratio, this is what actually caps output. |
| Main motor | 200 kW | Matched to output and to compound viscosity. |
| Gearbox specific torque | up to 10.3 Nm/cm³ | Decides whether the unit can run at high torque continuously. TDS-D series. |
| Transformer capacity | 300–1,200 kVA | Check the site supply before signing. Frequently missed on export projects. |
| Power supply | 380 V / 50 Hz | Export projects should state the local voltage and frequency explicitly. |
Output is only half of what a specification fixes. On a CO₂ line the injection side is what decides the board rather than the throughput figure, and it has its own write-up: the CO₂ foam XPS line guide.
Board grades, dimensions and tolerances are as given in GB/T 10801.2-2018. Line figures are our standard XPS configuration; a project may specify otherwise, and the signed technical agreement takes precedence.
Further reading
Standards & Specifications
-
Key PVC Foam Board Production Line Technical SpecificationsExtruder, calibration and downstream figures for PVC foam board lines, section by section.
-
Disc Pulverizer for Plastic: 4 Specifications That MatterThe four pulverizer specifications that decide reclaim powder quality, and how each one behaves.
Selection & Buying Guides
-
High Efficiency CO2 Foam XPS Production Line GuideThe CO₂ injection side of an XPS line: what the specification covers and where the variables sit.
-
Efficient CO2-Free Foamed XPS Production Line Buying GuideWhat changes in the extruder modules when a line runs without CO₂, and which material limits tighten.
-
PVC Board Production Line Complete Buying Guide 2026A stage-by-stage account of specifying a PVC board line, from end product through to handover.
-
How To Choose Best KT Board Production LineAutomation level and extrusion process as the two variables that set KT board cost per unit.
-
Industrial Refiner Mill Complete Selection Guide For BeginnersMill architectures compared on running cost and hygiene requirements rather than purchase price.
-
How to Select a ZLYJ Gearbox for Single-Screw ExtrudersWhat the ZLYJ rated parameters cover, and the checks to run when a gearbox runs hot or loud.
Installation & Maintenance
-
PS Foam Underlayment Installation Guide for FloorsThickness limits for floors, underfloor heating and commercial work, plus the subfloor checks that apply.
-
PS Foam Wall Panel and Wall Decoration Production Line GuideHow moulding, skirting and wall panel specifications diverge off one line, and what the foaming route decides.
-
How To Clean Water ChillerCooling capacity lost to a fouled circuit, what to inspect before opening it, and when to call it in.
Support
Have a grade to meet, not a table to read?
Send the specification you have to hit: board class, dimensions, output. We will tell you whether our standard configuration reaches it, and where it does not.